Estimating Left Ventricular Mass from the Electrocardiogram across the Spectrum of LV Mass from Normal to Increased LV Mass in an Older Age Group
Read the full articleJournal profile
Cardiology Research and Practice publishes original research articles and review articles focusing on the diagnosis and treatment of cardiovascular diseases, including hypertension, arrhythmia, heart failure, and vascular disease.
Editor spotlight
Dr. Terrence Ruddy is Director of Nuclear Cardiology at the University of Ottawa Heart Institute, and Professor of Medicine and Radiology at the University of Ottawa. His research is in SPECT and PET imaging techniques in cardiovascular disease.
Special Issues
Latest Articles
More articlesChallenges in Effective Referral of Cardiovascular Diseases in Nepal: A Qualitative Study from Health Workers’ and Patients’ Perspective
Background. Nepal, currently facing a high burden of noncommunicable diseases (NCDs), including cardiovascular diseases (CVDs), which poses the highest mortality rate in the country, does not seem to have a proper referral strategy. This study explored the wide range of factors and challenges that affect the referral system of CVD cases in Nepal. Methods. In this qualitative study, we conducted face-to-face and telephone interviews with purposely selected 57 key participants which included 35 healthcare professionals from tertiary, secondary, and primary levels from Bagmati Province and 22 CVD patients (myocardial infarction and stroke) from Bagmati and Madhesh Provinces. We interviewed them using an interview guide with open-ended questions for in-depth information in a local language and in a private space. The interviews were audio-recorded, transcribed verbatim, coded, and analyzed using the thematic approach. Results. The findings indicated that the referral system for CVD cases from primary- to secondary- to tertiary-level care is inadequate and malfunctioning. The major factors affecting referral of CVD cases are centralization of CVD-specific services in few urban areas, inadequate systematic communication between the centers, self-referential, lack of human resources for CVD care, and obstacles to patient transfer due to geographical and financial reasons. Conclusion. A referral system for CVD patients is absent in the context of Nepal. Understanding and addressing key factors that affect the referral system of CVD patients may help to improve cardiac outcomes and ultimately save lives.
Optimizing Anesthetic Selection in Transcatheter Aortic Valve Replacement: Striking a Delicate Balance between Efficacy and Minimal Intervention
Patients with severe calcific native aortic valve stenosis (AS) who require valve replacement have two options, surgical aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR). TAVR was approved in late 2011 for extremely high-risk patients and was subsequently approved for high-risk (2012), intermediate-risk (2016), and low-risk (2019) patients. In 2019, TAVR procedures surpassed SAVR procedures for the first time in the United States. The approach to anesthesia for this procedure has also evolved. Initially, general anesthesia (GA) was preferred, but currently, conscious sedation (CS) is favored. This review aims to clarify the indications and contraindications for both approaches, as well as the advantages of one approach over the other. Recent studies show that conscious sedation has better outcomes in terms of all-cause mortality, procedure complications such as stroke, myocardial infarction, infection requiring antibiotics, acute kidney injury, and the need for inotropes or vasopressors.
The Comparison of the Initial TIMI Flow Grade in Acute ST-Elevation Myocardial Infarction Patients Receiving Ticagrelor vs. Clopidogrel before Undergoing Primary Percutaneous Coronary Intervention: A Prospective Cohort Study
Objective. Primary percutaneous coronary intervention (PCI) is the best treatment for acute ST-elevation myocardial infarction (STEMI). Evidence is in favor of ticagrelor over clopidegrel in STEMI patients regarding the reduction of stent thrombosis risk during and after PCI. We compared initial thrombolysis in myocardial infarction (TIMI) flow in STEMI patients on ticagrelor vs. clopidogrel. Methods. This prospective cohort recruited 160 patients with acute STEMI, referred to the emergency department of Farshchian Heart Center, during March 2018–2019. Before angiography, the patients received clopidogrel (600 mg) or ticagrelor (180 mg) on top of aspirin. Initial TIMI flow was compared between the two groups as the primary outcome. A logistic regression was performed to calculate the predictors of initial TIMI flow. Analyses were performed using R, version 4.2.1. Results. In ticagrelor and clopidogrel groups, the mean ± standard deviation age of the patients was 59.46 ± 13.11 and 61.34 ± 11.08 years ( value = 0.33), respectively. In the ticagrelor and clopidogrel groups, initial TIMI flow grades were as follows: 0 : 50% and 71.2%, I: 26.2% and 16.2%, II: 12.5% and 10%, and III: 12.9% and 2.5%, respectively ( value = 0.005). Final TIMI flow grades were as follows: I: 26.2% and 16.2%, II: 7.5% and 13.8%, and III: 66.3% and 70%, respectively ( value = 0.41). Ticagrelor was associated with significantly higher initial TIMI flow grade compared to the clopidogrel group (adjusted odds ratio: 2.90 (95% CI: 1.51–5.72)). Conclusion. In STEMI patients who were candidates for primary PCI, ticagrelor administration led to a better initial TIMI flow grade compared to clopidogrel.
Relationship between Brain Natriuretic Peptide and Thromboembolic Events in Elderly Patients with Nonvalvular Atrial Fibrillation
Objective. To investigate the relationship between brain natriuretic peptide (BNP) and thromboembolic events in elderly patients with nonvalvular atrial fibrillation (NVAF). Methods. This is a prospective cohort study, and based on the inclusion and exclusion criteria, 180 elderly patients with NVAF were included. The patients received follow-up appointments in the clinic or by telephone every 6 months after the beginning of the study. The primary follow-up endpoints were thromboembolic and atherosclerotic events, including ischaemic stroke, myocardial infarction, and systemic embolism. The secondary endpoints were adverse events, including cardiovascular death, all-cause death, and hospitalisation for heart failure. Patients were divided into three groups according to their BNP level at admission: group A (BNP ≤334.5 pg/mL), group B (BNP = 334.5–1,288 pg/mL), and group C (BNP ≥1,288 pg/mL). Results. A total of 180 patients were enrolled in this study, with 50 patients in group A, 68 in group B, and 62 in group C. Compared with groups A and B, group C had a higher CHA2DS2-VASc score (Z = 15.142; ) and a lower ejection fraction (EF) value (Z = 119.893; ). The left atrium (LA) and left ventricular end-diastolic diameter (LVEDD) were larger (Z = 105.031; and Z = 74.430; ), respectively, suggesting that patients with significantly increased BNP had a higher risk of thromboembolism and atherosclerosis, lower EF, larger LA and LVEDD, and worse cardiac function. After 1 year of follow-up, the incidence of primary endpoint events (χ2 = 9.556; ) and secondary endpoint events (χ2 = 59.485; ) in group C were higher than those in groups A and B. Conclusion. Higher BNP levels may be an independent risk factor for thromboembolic and atherosclerotic events in elderly patients with NVAF. The higher the BNP level, the greater the risk of thromboembolic and atherosclerotic events.
Global Longitudinal Strain May Be the One that Appropriately Identifies Candidates of ICD Implantation
Hypertrophic cardiomyopathy (HCM) significantly contributes to an elevated risk of sudden cardiac death. Primary prevention is implemented by using an implantable cardioverter defibrillator (ICD). However, all of the HCM patients do not really need ICD therapy. Providing a superior index for ICD indication compared with the current indices like ejection fraction is essential to differentiate high-risk patients efficiently. The present study assessed the potential of global longitudinal strain (GLS) for the differentiation of HCM patients based on their need for ICD shocks. Patients with HCM were considered in four defined centers between March and June 2021. Those with previous ICD implantation or current candidates for ICD therapy were included in the study. Participants were subjected to speckle-tracking echocardiography, and GLS as well as some other echocardiographic parameters were recorded. Afterwards, data from implanted ICDs were extracted. Patients who received ICD shocks (appropriate) due to ventricular tachycardia (VT)/ventricular fibrillation (VF) were categorized in group A. The remaining patients were constituted group B who received inappropriate shocks, i.e., other than VT/VF. Overall, 34 patients were found eligible to participate with a mean age of 62 ± 16.1 years including 64.7% of males. Among a variety of echocardiographic parameters, GLS was the sole one that was significantly higher in group A compared with that in group B. Our findings revealed that only GLS could predict fatal arrhythmias. To substantiate, the odds of VT were raised by 43% with a single increase in GLS unit. GLS showed the highest accuracy for ICD indication among HCM patients and, therefore, could be a solid and early criterion to predict the incidence of life-threatening arrhythmias. In this regard, identifying appropriate HCM patients with respect to their need for ICD therapy is feasible.
Performance and Physician Experience of INGEVITY+ Active Fixation Leads: Prospective INGEVITY+ Lead Clinical Study in Korea
Background. Boston Scientific INGEVITY+ pacing lead (Boston Scientific, Marlborough, MA, USA) has been upgraded to INGEVITY. The performance of the INGEVITY+ pacing lead has not yet been reported. This study aimed to evaluate the short- and long-term safety, effectiveness, and handling experience of INGEVITY+ leads. Methods. Consecutive patients were included from 9 institutions in Korea, where 400 leads (200 right ventricular active fixation leads and 200 right atrial active fixation leads) were implanted or attempted in 200 subjects. Results. During the implantation, only one patient required a lead change because of lead screw failure. The handling questionnaires of the lead received very positive feedback with 88% of operators agreeing that it is easy for leads to pass through small vessels or vessels with multiple leads. At the 3-month follow-up, 95.7% of RA leads and 99.5% of RV leads had pacing thresholds less than 1.5 V. A total of 92.4% of atrial leads had amplitudes greater than 1.5 mV, and 96.5% of ventricular leads had sensing amplitudes greater than 5 mV at 3 months. A total of 99.8% had impedances between 300 and 1,300 ohms. The lead-related complication-free rate for all leads during follow-up was 100%, and the overall rates of lead dislodgment, perforation, and pericardial effusion were all 0.0%. Conclusions. The INGEVITY+ pacing lead exhibited exceptional clinical performance, with a high complication-free rate throughout the 3-month follow-up period. In addition, the lead displayed excellent electrical characteristics, and the lead-handling experience was reported to be very good.