Research Article

Plasma Fibulin-3 as a Potential Biomarker for Patients with Asbestos-Related Diseases in the Han Population

Table 3

AUC and cutoff value of plasma fibulin-3 for diagnosing ARDs.

AUC (95% CI)Cutoff value (ng/ml)Sensitivity (%)Specificity (%) value

MPM versus control0.92 (0.81–1.00)15.3086.6797.87<0.001
MPM versus AE0.88 (0.75–1.00)15.8486.6791.89<0.001
MPM versus PP0.90 (0.78–1.00)15.8686.6793.58<0.001
MPM versus asbestosis0.81 (0.67–0.96)15.6986.6775.860.001
Asbestosis versus controls0.67 (0.55–0.79)14.8831.0397.870.007
AE versus controls0.61 (0.53–0.70)12.2641.8977.660.014
PP versus controls0.57 (0.50–0.64)8.4090.8323.400.040

AUC: area under the curve; CI: confidence interval; PP: pleural plaque; MPM: malignant pleural mesothelioma; AE: asbestos-exposed subjects; ARDs: asbestos-related diseases.