Clinical Study

Plain Radiography May Be Safely Omitted for Selected Major Trauma Patients Undergoing Whole Body CT: Database Study

Table 3

Performance characteristics of plain films compared to CT.

Performance characteristicPelvis ( )Chest ( )
95% CI95% CI

Sensitivity94.985.8–98.959.952.0–67.4
Specificity74.463.6–83.495.778.1–99.9
Negative predictive values95.386.9–99.024.716.2–35.0
Positive predictive value72.761.4–82.399.0 94.6–100
Likelihood ratio of a positive test3.72.4–5.913.82.4–674.0
Likelihood ratio of a negative test0.070.01–0.20.40.4–0.7