Performance characteristics of plain films compared to CT.
| Performance characteristic | Pelvis () | Chest () | | 95% CI | | 95% CI |
| Sensitivity | 94.9 | 85.8–98.9 | 59.9 | 52.0–67.4 | Specificity | 74.4 | 63.6–83.4 | 95.7 | 78.1–99.9 | Negative predictive values | 95.3 | 86.9–99.0 | 24.7 | 16.2–35.0 | Positive predictive value | 72.7 | 61.4–82.3 | 99.0 | 94.6–100 | Likelihood ratio of a positive test | 3.7 | 2.4–5.9 | 13.8 | 2.4–674.0 | Likelihood ratio of a negative test | 0.07 | 0.01–0.2 | 0.4 | 0.4–0.7 |
|
|