Fault property sheet.

Fault nameActivity stopping timeRelationship between the fault lateral extension and caprockRelationship between the fault throw and caprock thicknessLargest fault dip angle (°)Vertical permeability (103 mD)Fault rock thickness (m)Minimum displacement pressure (MPa)Minimum formation pressure (MPa)Lateral displacement workLateral permeability (10−7 mD)Closed coefficientUpthrown
SGR (%)
Upthrown SSFDownthrow
SGR (%)
Downthrow
SSF

F1The late GuantaoBroken through typeSeal connected type6211.0219.6131.60025348.248.11.90300.76//
F2The late GuantaoBroken through typeSeal connected type4911.0418.30229.79710203.582.41.98700.3325–357
F3ES3MEmbedded typeSeal connected type5211.0317.72429.0597278.3211.71.98800.2224–325.5
F4Before the depositing of ES2Embedded typeSeal connected type4111.0316.87227.89610447.259.52.00700.3325–454
F5Before the depositing of ES2Embedded typeSeal connected type4811.0316.4227.30415459.134.21.87900.5415–209
F6Before the depositing of ES2Embedded typeSeal connected type4911.0318.63230.25015209.751.71.98300.4310–158
F7Before the depositing of ES2Embedded typeSeal connected type5211.0219.72931.8278020.8874.01.97700.2210–182.4
F8Before the depositing of ES2Embedded typeSeal connected type4611.0318.75730.6096981.5681.31.92200.2218–328.7
F9Before the depositing of ES2Embedded typeSeal connected type4711.0320.02532.3427405.9842.01.92700.2220–322
F10Before the depositing of ES2Embedded typeSeal connected type5211.0119.4430.72310641.433.22.10000.3325–407.2
F11Before the depositing of ES2Embedded typeSeal connected type5511.0219.33131.2418582.5521.01.92800.2615–257.5
F12Before the depositing of ES2Embedded typeSeal connected type4511.0316.1526.6653330.4981.13.14700.11226.2
F13Before the depositing of ES2Embedded typeSeal connected type4411.0215.62726.2592961.8565.02.33700.1128–305.2
F14Before the depositing of ES2Embedded typeSeal connected type4511.0317.16728.2835656.7512.81.99200.1718–266.7
F25The end of ES3X depositEmbedded typeSeal connected type4111.0316.96228.0403182.1961.22.06200.2816–207.5
F15The end of ES3X depositEmbedded typeIntact top seal type4011.0318.5530.1378951.2032.01.76325–350.7532–440.75
F21The end of ES3X depositEmbedded typeSeal connected type4811.0316.82527.8343157.9411.52.165322322