Research Article
Immunochemical Fecal Occult Blood Test for Detection of Advanced Colonic Adenomas and Colorectal Cancer: Comparison with Colonoscopy Results
Table 4
FIT performance in detecting CRC and advanced adenomas.
| | CRC () | Advanced adenomas () |
| Sensitivity % (IC 95%) | 88.9 (52–99) | 63.6 (31–89) | Specificity % (IC 95%) | 87.6 (83–91) | 87.6 (83–91) | Positive predictive value % (IC 95%) | 18.6 (8–33) | 16.7 (7–31) | Negative predictive value % (IC 95%) | 99.6 (97–99) | 98.4 (96–99) |
|
|