Clinical Study

Clinical Impact of Prophylactic Antibiotic Treatment for Self-Expandable Metallic Stent Insertion in Patients with Malignant Colorectal Obstruction

Table 2

Comparison of procedure-related outcomes in PA versus Non-PA groups.

CharacteristicsPA group ()Non-PA group () value

Stent type (covered/uncovered)62 (42.8%)/83 (57.2%)29 (36.7%)/50 (63.3%)0.397
Stent length (<10 cm/≥10 cm)99 (68.3%)/46 (31.7%)52 (65.8%)/27 (34.2%)0.766
Stent diameter (≤22 mm/>22 mm)63 (43.4%)/82 (56.6%)28 (35.4%)/51 (64.6%)0.244
Technical success139 (95.9%)74 (93.7%)0.524
Clinical success142 (97.9%)75 (94.9%)0.240
Complications
 Perforation 4 (2.8%)2 (2.5%)1.000
 Migration17 (11.7%)8 (10.1%)0.826
 Reobstruction13 (9.0%)6 (7.6%)0.807
 Fever 9 (6.2%)6 (7.6%)0.781
 SIRS19 (13.1%)5 (6.3%)0.174
 Bacteremia/blood culture 5/96 (5.2%)3/41 (7.3%)0.696
Time interval (hours)
between symptom onset and stent insertion
232.8 ± 200.2233.1 ± 150.50.529

WBC, white blood cell; ANC, absolute neutrophil count; CRP, C-reactive protein; PA, prophylactic antibiotic; SIRS, systemic inflammatory response.