Research Article

Molecular Analyses of Aspirated Cystic Fluid for the Differential Diagnosis of Cystic Lesions of the Pancreas: A Systematic Review and Meta-Analysis

Table 3

Accuracy measures of molecular diagnostic analyses for the differentiation of mucinous from nonmucinous pancreatic cysts.

TestAccuracy measurePooled summary measure# (95% CI) value of heterogeneity test

KRAS mutation testsSensitivity0.47 (0.39–0.54)0.01
Specificity0.98 (0.93–0.99)0.67
Positive likelihood ratio10.03 (3.72–27.06)0.36
Negative likelihood ratio0.56 (0.43–0.73)0.06
Diagnostic odds ratio19.69 (5.91–65.58)0.27

LOH testsSensitivity0.63 (0.54–0.71)0.17
Specificity0.76 (0.63–0.87)0.18
Positive likelihood ratio2.23 (1.35–3.66)0.67
Negative likelihood ratio0.54 (0.42–0.70)0.61
Diagnostic odds ratio4.65 (2.14–10.09)0.77

#Random effects model. Chi-square or Fisher’s exact test for heterogeneity. .