Research Article
A Single-Stage Isolated Battery Charger Using Nonbridged Positive Cuk Converter Configuration
Table 1
Comparative analysis of NB-IPCuk converter with different existing BL configurations.
| S. no. | Configuration | Device count | L | C | X | D | Switch | Total |
| 1. | NB-Landsman [25] | 4 | 4 | 1 | 5 | 2 | 16 | 2. | NB-Cuk [20] | 6 | 6 | 1 | 5 | 2 | 20 | 3. | NB-SEPIC [21] | 4 | 6 | 1 | 5 | 2 | 16 | 4. | NB-Luo [22] | 4 | 4 | 1 | 5 | 2 | 16 | 5. | NB-Sheppard Taylor [23] | 4 | 4 | 1 | 11 | 4 | 24 | 6. | NB-IPCuk converter | 3 | 5 | 2 | 3 | 2 | 15 |
|
|