Actuator Fault Diagnosis in a Boeing 747 Model via Adaptive Modified Two-Stage Kalman Filter
Figure 3
Actual state variables and estimations when a stuck fault in stabilizer occurred at 20 seconds. Since actual and estimated state variables are too close, two curves are seen as one curve.