Research Article

A Novel Method for Recognition of Bioradiolocation Signal Breathing Patterns for Noncontact Screening of Sleep Apnea Syndrome

Table 2

Selection of the optimal number of hidden neurons for NNW.

Number of neuronsRecognition accuracy values

10,3600,4550,4790,4790,431
20,5610,6200,5620,6200,581
30,7320,6750,7460,7460,718
40,7300,7930,7340,7930,752
50,7890,8230,7560,8230,789
60,7680,8180,8080,8180,798
70,7990,8420,8140,8420,818
80,8210,8250,8150,8250,820
90,8360,8500,8360,8500,841
100,8130,8480,8330,8480,831
110,8200,8390,8120,8390,824
120,8210,8310,8250,8310,826
130,8360,8230,8270,8360,829
140,7880,8200,8180,8200,809
150,8240,7820,7940,8240,800

Where , , and are mean BPBS recognition accuracy values for corresponding wavelet bases (Dobeshi 13, Symlet 13, and Coiflet 5) at the set number of hidden neurons of NNW; is the maximum BPBS recognition accuracy value; is MRA estimate.