Research Article

Illustration of the Impedance Behaviour of Extremely Low-Profile Coupled Shorted-Patches Antennas for UHF RFID of People

Table 2

Measured maximum identification distance in the corridor of building 4 m in width and 3.5 m in height.

Tested configurationReader and tag antenna axis offset m Reach of correct identification [m]

Dipole-excited antenna on the chest of a person07.5
1.87

Directly excited antenna on the chest of a person07
1.86