Imaging-Assisted Large-Format Breast Pathology: Program Rationale and Development in a Nonprofit Health System in the United States
Table 5
Comparison of 135 consecutive breast conserving surgical specimens with DCIS. Conventional pathology without MRI (CP) and large format breast pathology with MRI (LBP).
CP
LBP
One or more of six margins measuring 0–4 mm
20 (47%)
22 (24%)
One or more of six margins measuring 0–9 mm
23 (54%)
31 (34%)
Re-excised after breast conservation
14 (32%)
11 (12%)
Volume of breast conservation specimen, median (cm3)