Research Article

Hybrid Mammogram Classification Using Rough Set and Fuzzy Classifier

Table 3

Results of PCA-ICA-Fuzzy, PCA-ICA-Rough-Fuzzy, PCA-Fuzzy, PCA-Rough-Fuzzy, ICA-Fuzzy, and ICA-Rough-Fuzzy algorithms. NA: not applicable.

AlgorithmSet no.PCFPFNAccuracyPrecisionRecall

PCA-ICA-Rough-Fuzzy1821.85%9.24%68.91%56.66%75.56%
279.24%7.56%83.19%81.67%84.49%
3812.61%12.61%74.79%74.99%74.99%
4810.08%5.88%84.03%80.01% 87.28%

PCA-ICA-Fuzzy1816.81%14.28%68.91%66.66%70.18%
22010.92%5.89%83.19%78.34%87.02%
3612.61%21%66.39%74.99%64.29%
458.4%9.25%82.35%83.34%81.96%

PCA-Fuzzy12026.05%10.08%63.87%48.33%70.74%
2510.08%14.29%75.63%80.01%73.84%
3612.61%21%66.39%74.99%64.29%
4511.75%7.58%80.67%76.7%83.61%

PCA-Rough-Fuzzy11620.17%18.49%61.35%60%62.06%
259.25%10.08%80.67%81.65%80.33%
3616.81%17.65%65.55%66.66%65.57%
4810.08%10.08%79.83%80.01%80.01%

ICA-Fuzzy1NA10.08%40.34%49.58%80.01%50%
2NA10.08%40.34%49.58%80.01%50%
3NA10.08%40.34%49.58%80.01%50%
4NA10.08%40.34%49.58%80.01%50%

ICA-Rough-Fuzzy1NA15.97%15.13%68.91%68.33%69.48%
2NA10.08%9.24%80.67%80.01%81.36%
3NA14.29%18.49%67.22%71.66%66.15%
4NA8.4%11.77%79.83%83.34%78.12%