Research Article

Compressed Sensing Photoacoustic Imaging Based on Fast Alternating Direction Algorithm

Table 1

Numerical results for L1magic, SPGL1, and ADM methods on PAI images with different sampling angles and 64 Fourier samples per angle uniformly covering the 90-degree view.

PositionsExperimental
IterationsCPU time (seconds)SNR (dB)
Magic SPGADMMagic SPGADMMagic SPGADM

166734088471.216.35.5−3.8−3.6−3.5
247542273692.128.73.40.70.93.9
327734568831.529.57.93.33.43.6
407835058877.537.56.611.112.113.4
4880337531280.743.29.311.111.713.8
5679317461294.245.34.120.324.628.6
6479429431179.664.55.020.422.125.9
7281367461711.966.46.021.222.928.7
8084366421580.968.711.422.729.129.7

Average1102.244.56.6