Research Article

Automated Segmentation and Object Classification of CT Images: Application to In Vivo Molecular Imaging of Avian Embryos

Table 3

Classification accuracy of the SVM on the test data from Group 2 eggs.

ClassesTrue positive rateFalse positive ratePrecisionRecallF-measureROC-area

Humerus0.8750.0001.0000.8750.9330.966
Radius0.9380.0020.8820.9380.9090.999
Ulna0.8640.0020.9050.8640.8840.999
Carpometacarpus0.8750.0001.0000.8750.9330.965
Femur0.9580.0001.0000.9580.9790.975
Tibiotarsus0.8750.0001.0000.8750.9330.978
Tarsometatarsus0.9050.0010.9500.9050.9270.980
Not of interest (NOI)0.9990.0770.9890.9990.9940.989
Weighted avg.0.9860.0680.9860.9860.9880.989