Research Article
Experimental Investigation on Corrosion of Cast Iron Pipes
Table 4
Potentiostatic parameters and corrosion rate (CR).
| Solution and time of measurement | Pipe | | PR (ohms) | (mV/decade) | (mV/decade) | CR (mm/year) |
| Static tap water after one year | 1 | −0.692 | 85 | 478 | 250 | 0.136 | 2 | −0.695 | 54 | 359 | 221 | 0.146 | 3 | −0.685 | 75 | 402 | 244 | 0.136 |
| Aerated tap water after one year | 1 | −0.472 | 63 | 230 | 165 | 0.188 | 2 | −0.515 | 142 | 299 | 218 | 0.122 | 3 | −0.467 | 54 | 222 | 164 | 0.195 |
| Aerated solution of 3.5% NaCl after six months | 1 | −0.691 | 10 | 61 | 28 | 0.18 | 2 | −0.697 | 8 | 54 | 29 | 0.152 | 3 | −0.687 | 9 | 59 | 25 | 0.135 |
|
|