Research Article
Experimental Investigation on Corrosion of Cast Iron Pipes
Table 5
Tafel slopes and corrosion rate.
| Solution and time of measurement | Pipe | (mV/decade) | (mV/decade) | CR (mm/year) |
| Static tap water after one year | 1 | 123.5 | 131 | 0.074 | 2 | 116.9 | 118.85 | 0.12 | 3 | 182 | 197 | 0.12 |
| Aerated tap water after one year | 1 | 207.6 | 215.5 | 0.286 | 2 | 223.7 | 233 | 0.239 | 3 | 179.9 | 187.3 | 0.303 |
| Aerated solution of 3.5% NaCl after six months | 1 | 82.4 | 84.5 | 0.69 | 2 | 31 | 31.6 | 0.53 | 3 | 29.1 | 29.7 | 0.6 |
|
|