Research Article

Evaluation of Corrosion Behavior of Galvanized Steel Treated with Conventional Conversion Coatings and a Chromate-Free Organic Inhibitor

Table 2

Electrochemical data of the tested materials after immersion in 0.5 M NaCl for 1 h.

Condition   (mV/decade)   (mV/decade)   (μA/cm2) /   (mVsce)Corrosion rate (mpy)Ch Sq

Untreated8836711.9−1033/−10507.03.67
Inhibitor 5%442246.9−1046/−10804.03.75
Phosphated522011.8−1010/−10201.04.07
Chromated352781.1−1050/−10400.74.09