Research Article

Determination of Susceptibility to Intergranular Corrosion of UNS 31803 Type Duplex Stainless Steel by Electrochemical Reactivation Method: A Comparative Study

Table 4

EDS analysis of phases present in solution annealed and aged condition of DSS.

Heat treatmentPhase Cr
(wt.%)
Ni
(wt.%)
Mo
(wt.%)
Mn
(wt.%)
Si
(wt.%)
S
(wt%)
Fe
(wt%)

Solution annealedGeneral composition 22.04 4.45 2.69 1.49 0.45 0.00368.29

Solution annealed at 1050°C/1 hr 26.32 4.87 4.15 1.59 0.7462.32
23.55 7.08 1.85 1.1966.33

Aged at 800°C/31622 min 22.03 6.10 2.27 2.05 0.5666.98
19.97 7.20 2.22 0.7269.90
20.23 6.29 2.4171.08
32.15 2.26 6.66 1.80 0.7156.41
21.92 6.16 1.95 0.8069.17

Aged at 800°C/316 min 27.71 3.47 0.55 0.98 67.28
26.97 2.77 0.91 69.36
20.26 4.76 2.10 0.61 72.28
30.76 3.36 7.88 1.80 0.71 55.50