Research Article

Ultrasonic Measurement of Corrosion Depth Development in Concrete Exposed to Acidic Environment

Table 2

Experimental conditions.

DesignationExposing conditionSolution aciditySpecimen groupingImmersion time (days)

Series 1Pure waterpH 7.06 specimens in a group, 18 groups5, 10, 15, 20, 25, 30, 35, 40, 45, 55, 65, 75, 100, 105, 130, 180
Series 2H2SO4 + HNO3 (molar ratio is 9: 1)pH 3.56 specimens in a group, 15 groups5, 10, 15, 20, 25, 30, 35, 40, 45, 55, 65, 75, 100, 130, 180
Series 3H2SO4 + HNO3 (molar ratio is 9: 1)pH 2.56 specimens in a group, 15 groups5, 10, 15, 20, 25, 30, 35, 40, 45, 55, 65, 75, 100, 130, 180
Series 4H2SO4 + HNO3 (molar ratio is 9: 1)pH 1.56 specimens in a group, 11 groups5, 10, 25, 35, 45, 55, 65, 80, 90, 105, 130