Research Article

Corrosion Behaviour of Heat-Treated Aluminum-Magnesium Alloy in Chloride and EXCO Environments

Table 3

Gravimetric corrosion rate (mm/yr) for the 0.91% Mg specimen.

DaysNaCl solutionFeCl3EXCO solution
As-castRRAAs-castRRAAs-castRRA

00.0000.0000.0000.0000.0000.000
12000.0000.0000.7710.0000.0000.000
24000.0000.0000.7710.1930.1930.193
36000.0000.0000.6420.2570.1280.257
48000.0000.0000.5780.2890.1930.385
60000.0770.0000.540.2310.2310.308
72000.0640.0000.5150.2570.3220.322