Research Article

The Corrosion Performance of Galvanized Steel in Closed Rusty Seawater

Table 1

Electrochemical parameters of galvanized steel calculated from polarization curve at 0.1 MPa and 293 K in seawater and CRS solution.


V versus SCE

μA cm−2

mV/dec

mV/dec

Sea—2d−1.03615.17158.6220.3
Sea—7d−1.07322.91132.53234.2
Sea—14d−1.08937.12148.3235.5
CRS—2d−1.04118.5857.7211.2
CRS—7d−1.04325.5641.6186.3
CRS—14d−1.07558.3435.2196.4