Tab 2
/
Research Article
The Corrosion Performance of Galvanized Steel in Closed Rusty Seawater
Table 2
EIS fitting parameters of galvanized steel after various immersion times in CRL solution at 0.1 MPa under different temperatures (273, 293, 313, and 333 K).
Time
hours
Ω cm
2
F cm
−2
Ω cm
2
Q
2
F cm
−2
Ω cm
2
W
Ω cm
2
273 K
24
0.01
7.56
0.59
1235
102.5
0.59
5523
—
48
0.01
12.23
0.74
1356
241.8
0.68
4862
—
96
0.01
53.58
0.62
1478
91.5
0.58
5900
—
192
0.01
89.56
0.61
1563
101.8
0.65
6123
—
293 K
24
0.01
9.6
0.54
625.1
312.4
0.94
439.2
—
48
0.01
14.2
0.78
690.2
91.6
0.91
530.8
0.00412
96
0.01
21.2
0.95
714.5
242.8
0.61
459.9
0.00462
192
0.01
140.5
0.85
700.2
135.2
0.59
521.5
0.0189
313 K
24
0.01
130.1
0.60
131.2
25.3
0.74
725
—
48
0.01
52.3
0.59
162.6
252.7
0.59
714.4
—
96
0.01
40.9
0.63
187.2
245.3
0.62
736.5
—
192
0.01
190.5
0.52
168.9
23.5
0.68
778.3
—
333 K
24
0.01
41.2
0.57
58.6
169.2
0.65
270.3
—
48
0.01
56.5
0.61
108.5
452.1
0.71
286.4
—
96
0.01
94.5
0.59
117.3
475.5
0.62
290.5
—
192
0.01
156.4
0.88
139.5
412.7
0.58
298.6
—