Research Article

Statistics Analysis Measures Painting of Cooling Tower

Table 3

Thickness corrosion protection in μm of reinforcement for internal shell.

Thickness corrosion protection reinforcement for external shell.
Working jointsAverageMin.Max.Standard deviation (SD)Standard deviation (SD) (%)

6–12856.056001120231.1227.00
13–18945.237821105210.9522.32
19–25959.737501200232.7024.25
26–31 871.736411150231.9126.60
32–38866.686701100209.6424.19
39–45902.006501100222.9724.72
46–52892.527001027209.7523.50
53–59908.006451090208.7723.88
60–66971.766801150231.7323.85
67–71949.437001180221.8923.37
72–77955.717801190231.9824.27
78–84899.197101032208.6123.20
85–91899.006371110204.9821.98
92–98935.986891150216.3422.96
99–104890.877001027209.7523.50
105–111970.337191190256.9820.99
112–118928.056901074224.8724.23
125–131986.677231200241.9424.52
132–5948.387301190230.2824.28