Research Article

Inhibition of Corrosion of Carbon Steel in 3.5% NaCl Solution by Myrmecodia Pendans Extract

Table 1

The corrosion parameters obtained from polarization plots.

Concentration (mg/L) (mV) (μA) (mV/dec) (mV/dec)Corrosion rate (mpy)Efficiency inhibition (%)

0−753.745−323.257370.595193.26995.93
100−612.544−62.70577.561127.5718.60874.28
200−813.921−56.62463.86499.9216.80379.85
300−699.827−26.35938.38747.687.82290.39
400−620.445−19.22236.77242.585.70491.41
500−638.899−28.09746.09760.738.33887.75