Research Article
Inhibition of Corrosion of Carbon Steel in 3.5% NaCl Solution by Myrmecodia Pendans Extract
Table 1
The corrosion parameters obtained from polarization plots.
| Concentration (mg/L) | (mV) | (μA) | (mV/dec) | (mV/dec) | Corrosion rate (mpy) | Efficiency inhibition (%) |
| 0 | −753.745 | −323.257 | 370.595 | 193.269 | 95.93 | — | 100 | −612.544 | −62.705 | 77.561 | 127.57 | 18.608 | 74.28 | 200 | −813.921 | −56.624 | 63.864 | 99.92 | 16.803 | 79.85 | 300 | −699.827 | −26.359 | 38.387 | 47.68 | 7.822 | 90.39 | 400 | −620.445 | −19.222 | 36.772 | 42.58 | 5.704 | 91.41 | 500 | −638.899 | −28.097 | 46.097 | 60.73 | 8.338 | 87.75 |
|
|