Research Article

Sealing of PEO Coated AZ91 Magnesium Alloy Using La-Based Solutions

Table 2

Values of the corrosion current density and corrosion potential for samples sealed with 12 g/l of La(NO3)3 at different temperature and for different treatment times, after PEO treatment.

(V) (A/cm2)

Untreated−1.882.00 × 10−5
PEO−1.871.50 × 10−6
12 g/l La 30°C 10 min−1.738.00 × 10−7
12 g/l La 30°C 30 min−1.834.00 × 10−7
12 g/l La 40°C 10 min−1.825.00 × 10−7
12 g/l La 40°C 30 min−1.692.80 × 10−7
12 g/l La 50°C 10 min−1.739.00 × 10−7
12 g/l La 50°C 30 min−1.652.80 × 10−7