Research Article

Electrolyte Composition for Distinguishing Corrosion Mechanisms in Steel Alloy Screening

Table 3

Characteristic values for potentiodynamic polarization scans in phosphate buffer with 3.5 wt.% NaCl.

AlloyMetastable pit growth

AISI 304−336.3 mV78.4 mV−12.7 mV–78.4 mV
AISI 420−617.2 mV−85.3 mV−172.7 mV–−85.3 mV
AISI 5210−663.7 mV