Power consumption per unit mass from CFD and experimental [1, 2].

Sr. no.RPMAq flow rate (mL per min) (m)  (m/s)  W/kg (present CFD) ( ) × 104 (Dehkordi [1, 2])

16003000.206.36581837
210003000.206.361492275
314003000.206.363762819
46001900.204.03501354
510001900.204.031801520
614001900.204.033702005
76001100.202.3350837
810001100.202.331771033
914001100.202.333971328