Reasonable range of decision variables.

Decision variablesLower boundUpper bound

Gasification temperature (K)9501150
Combustion temperature (K)13001400
Compressor pressure ratio (—)711
Moisture content of biomass (—)0.10.6
Temperature inlet to the chiller (K)383460
Bypass ratio (—)0.20.8
Maximum pressure of ORC (kPa)8001200