Research Article
Accuracy of Multiple Pour Cast from Various Elastomer Impression Methods
Table 3
The mean measurement values of stone dies, standard errors, and percentage of errors from master cast from Monophase impression technique.
| Measurement | First pour (1 Hr) | Second pour (12 Hr) | Third pour (24 Hr) | Fourth pour (48 Hr) | | Mean | SD | % | Mean | SD | % | Mean | SD | % | Mean | SD | % |
| Upper dia-abutment1 | 10.06 | 0.08 | 0.70 | 10.09 | 0.07 | 1.00 | 10.13 | 0.07 | 1.20 | 10.10 | 0.05 | −0.70 | 0.000 | Lower dia-abutment1 | 15.71 | 0.08 | 0.51 | 15.76 | 0.07 | 0.63 | 15.80 | 0.07 | 0.83 | 15.78 | 0.07 | 0.70 | 0.002 | Interabutment distance | 15.12 | 0.05 | 1.27 | 15.15 | 0.06 | 1.47 | 15.15 | 0.05 | 1.47 | 15.13 | 0.03 | 0.73 | 0.074 | Height abutment1 | 8.16 | 0.17 | −0.48 | 8.14 | 0.07 | −0.73 | 8.09 | 0.08 | −1.34 | 8.12 | 0.11 | −0.97 | 0.124 |
|
|