Research Article

Evaluation of the Water Quality Status and Pollution Load Carrying Capacity of Way Umpu River, Way Kanan District, Lampung Province, Indonesia, Based on Land Use

Table 3

Analysis of load capacity of Way Umpu downstream.

No.Parameter/riverUnitSampling locationStandard Class III
ST-1ST-2ST-4ST-6ST-7

1River discharge(m3/sec)12.461.20.310.784.5
2Water Temp°C27.9 ± 0.127.6 ± 0.129.2 ± 0.327.9 ± 0.127.7 ± 0.1
3TDSmg/L28 ± 1.424.5 ± 1.142.1 ± 1.231.2 ± 0.226.0 ± 0.61,000
4TSSmg/L7.4 ± 0.412 ± 1.0235 ± 2.81 0.8 ± 0.412.0 ± 0.7100
5ColorPt-Co38.7 ± 2.840.5 ± 1.7181 ± 7.142.3 ± 2.841.0 ± 1.3100
6TurbidityNTU4.9 ± 0.65.8 ± 0.170.6 ± 6.49.4 ± 0.46.4 ± 0.2
7pH7.8 ± 0.17.4 ± 0.16.7 ± 0.37.7 ± 0.27.6 ± 0.16–9
8Salinityo/oo00000 ± 0
9BODmg/L2 ± 0.32.2 ± 0.39.7 ± 0,22.0 ± 0.12.2 ± 0.26
10CODmg/L1.9 ± 0.14.4 ± 0.422.4 ± 1.64.1 ± 0.24.0 ± 0.440
11DOmg/L3.9 ± 0.63.8 ± 0.13.9 ± 0.63.7 ± 0.33.8 ± 0.23
12P (PO4)mg/L0.4 ± 0.010.5 ± 0.040.3 ± 0.020.4 ± 0.040.4 ± 0.11
13N (NO3)mg/L0.5 ± 0.010.7 ± 0.061.7 ± 0.041.5 ± 0.40.7 ± 0.0120
14Cdmg/L0.0002 ± 00.0002 ± 00.0002 ± 00.0002 ± 00.0002 ± 00.01
15Crmg/L0.0003 ± 00.0003 ± 00.0003 ± 00.0003 ± 00.0003 ± 00.01
16Cumg/L0.002 ± 0.0010.003 ± 0.0010.002 ± 0.00030.002 ± 0.0010.003 ± 0.00090.02
17Pbmg/L0.001 ± 0.0010.001 ± 0.00010.001 ± 0.00010.0008 ± 0.0010.001 ± 0.00020.03
18Hgmg/L0.0002 ± 00.0002 ± 00.0002 ± 00.0002 ± 00.0002 ± 00.002
19N (NO2)mg/L0.002 ± 0.0020.003 ± 0.0010.008 ± 0.0010.007 ± 0.0030.003 ± 0.00030.06
20Cnmg/L0.01 ± 00.01 ± 00.01 ± 00.01 ± 00.01 ± 00.02
21Fecal coliformMPN/100 mL7.2 ± 0.39.4 ± 1.011 ± 1.47.2 ± 0.38.8 ± 0.62,000
22Total coliformMPN/100 mL7.2 ± 0.39.4 ± 1.011 ± 1.47.2 ± 0.28.8 ± 0.710,000

Note. Standard according to reference Local Regulation of Lampung Province [20]. ST-7 = prediction result of pollution carrying load capacity of each water quality parameter [17].