Abstract

This paper reports, for the first time, the online monitoring to the electrochemical degradation of the paracetamol using a biomimetic sensor coupled to a Flow Injection Analysis (FIA) system. The electrochemical degradation of the drug was carried out in aqueous medium using a flow-by reactor with a DSA anode. The process efficiency was monitored at real time by the biomimetic sensor constructed by modifying a glassy carbon electrode with a Nafion membrane doped with iron tetrapyridinoporphyrazine (FeTPyPz). Simultaneously, we carried out off-line analysis by liquid chromatography (HPLC) during the experiments in order to validate the proposed system. In addition, to investigate the degradation products of the paracetamol electrolysis, we used the techniques of UPLC/MS and GC/MS.

1. Introduction

The environmental sciences have an enormous progress in recent years. The need for planning the rational use of energy resources and water provided a challenge for the applied sciences and engineering to develop new technologies, new processes, and new materials for the prevention and control of pollution. This is also a consequence of the increase of legal pressure that is forcing the industry to accept responsibility for waste treatment or storage, in an attempt to minimize pollution [1].

Oxidative conventional treatments, which may be chemical or biological, of aqueous solution containing organic compounds, are often effective in enforcement. However, this action is not enough nowadays, when environmental considerations should be considered. The conventional technology for wastewater treatment requires chemical storage and handling of hazardous chemicals and leads to the generation of toxic waste. Moreover, biological treatment is time consuming and performed in large physical areas, which also leads to the generation of soluble non-biodegradable waste. In addition, compounds with high molecular weight of fractions present in some types of aqueous effluents tend to be resistant to biodegradation [2].

In this field, the electrochemical and photochemical technologies may offer an efficient way for pollution controls, providing the degradation of organic pollutants without the disadvantages observed with conventional treatments. Electrolysis, heterogeneous photocatalysis, and photoassisted electrolysis can be used as primary or additional treatment at reduction of the organic matter. In fact, electrons and photons are the unique reagents added to the treatment process that basically does not generate subproducts [3].

The electrolytic process is probably the best tool in the treatment of aqueous effluent, ideal for the present, where environmental considerations are always ahead [2].

The literature outlines the principles and mechanisms for electrochemical treatment of aqueous solutions containing organic compounds with simultaneous oxygen evolution [4, 5]. The key to efficient electrolytic treatment is strongly based on the choice of anodic material. The high resistance to corrosion of the anode and physical and chemical stability under high applied potentials are the main requirements for an efficient process. When the above properties are required, dimensionally stable anodes (DSAs) are the natural candidates. This designation denotes a class of electrodes thermally prepared where a titanium substrate is covered by metallic oxides. Coatings include TiO2, IrO2, RuO2, and Ta2O5. Combinations such as TiO2/RuO2 are indicated for the alkaline medium, while IrO2/Ta2O5 usually shows longer useful life in acid electrolytes. Moreover, some DSA electrodes may receive addition of SnO2 and Sb2O5 in concentrations ranging appropriately, aiming to increase lifetime and eventually their catalytic power and selectivity [6, 7]. Currently, are commercialized some DSA anodes, between them is the DSA-Cl2 that is composed for a mixture of 70% of TiO2 and 30% of RuO2 and was used in the electrochemical degradation of paracetamol in this work.

On the other hand, biomimetic sensors are a recent experimental strategy that has been used to get chemical sensors more stables and durable that the conventional biosensors, that are based on the use of biological materials, such as enzymes or antibodies. These devices aim at to overcome the limitations of the enzymatic biosensors such as availability, cost, and instability of enzymes as well as to promote improvement in the electronic transfer between electrode/active site (biomimetic catalyst)/subtract, since that in the biomimetic sensors the “active site” is free, differently from in the enzymes, where the active site is surrounded by a dense layer of residual aminoacids [8, 9]. However, a condition to mimic or to choose an enzyme for the construction of biomimetic sensors is that the chemistry of the enzymatic reaction catalysis and the structure of its active site should be very well known, and in this sense the P450 enzymes are perfectly fitted in these conditions [9].

In previous papers [10, 11] were described the studies carried out to develop an amperometric sensor based on the use of iron tetrapyridinoporphyrazine (FeTPyPz), a biomimetic catalysts of the P450 enzyme, and its coupling and application satisfactory in the paracetamol detection in an FIA system. Due to the excellent characteristics shown by this FIA system using the biomimetic sensor as detector, and being recognized the importance of the degradation of organic compounds by means electrochemistry, this paper intends to demonstrate the viability of the use of sensors highly selective, stable, and durable, in monitoring online and in real-time of the paracetamol electrochemical degradation, as an alternative tool to existing methods for the offline monitoring, that may be time consuming, expensive, pollutants, and often not selective, as are the cases of the chemical oxygen demand and total organic carbon (TOC). Thus, this paper shows the promising junction of two areas of recent and increasing concern, the electrochemical and electroanalysis.

2. Experimental

2.1. Chemicals and Solutions

All chemicals used in the construction and application of the sensor were analytical grade reagents. All chemicals used in the chromatographic experiments were high-performance liquid chromatography (HPLC) grade reagents. The biomimetic complex, iron (III) tetrapyridinoporphyrazine (FeTPyPz), was prepared and purified as previously described [12]. Acetic acid and N,N-dimethylformamide (DMF) were acquired from Synth (São Paulo, Brazil). Paracetamol (acetaminophen) was obtained from Sigma (St. Louis, USA). 5% (m/v) Nafion solution was from Aldrich (Milwaukee, USA). Sodium acetate was acquired from Merck (Darmstadt, Germany), and all HPLC grade solvents were from Tedia (Rio de Janeiro, Brazil). Paracetamol and acetate buffer solutions were prepared with water purified in a Millipore Milli-Q system, and the pH was determined using Thermo Scientific pH-meter (Orion 3 Star, Benchtop).

2.2. Electroanalytical Flow System

The biomimetic sensor was constructed as previously described [10, 11]. First, a solution containing 5 mg mL−1 of the FeTPyPz in DMF was prepared. Then, the surface of a glassy carbon (GC) electrode (Metrohm, Switzerland), with a geometrical area of 0.126 cm2, was cleaned according to the procedure described in the literature [13]. After cleaning the electrode, 100 μL of FeTPyPz solution was mixed with 50 μL of 5% (m/v) Nafion solution, and an aliquot of 50 μL of this mixture was placed on the surface of the electrode. Finally, the solvent was evaporated at room temperature during 6 hours, forming a thin green film.

The biomimetic sensor was inserted into a flow-through wall-jet amperometric cell and used as the working electrode (WE in Figure 2). An Ag ∣ AgCl (KClsat) electrode was the reference (RE), and a platinum wire was the auxiliary electrode (AE). The electrodes were connected to a potentiostat (Palm-sense, Palm Instruments BV, The Netherlands) interfaced to a microcomputer for potential control and data acquisition.

A peristaltic pump (Ismatec) was used to provide the flow of the 0.1 mol L−1 K2SO4 and 5.0 × 10−4 mol L−1 FeSO4·7H2O carrier solution at 1.25 mL min−1. The standards and samples containing paracetamol were injected (loop = 75 μL) into the carrier using a sliding central bar sampling valve (injector) [14].

2.3. Electrochemical Degradation System

To carry out the electrolysis, was used a flow-by electrochemical reactor with a compartment constructed with PVC plates mounted in the form of a filter press, designed to be coupled to a reservoir with a capacity of 2.5 L [15, 16]. The reactor used a gas diffusion electrode (GDE) containing 20% (w/w) polytetrafluoroethylene (PTFE) acting as a carbon cathode with geometric area of 20 cm2 and a commercial anode of DSA-Cl2 by De Nora do Brazil Ltda [17] (with a geometrical area of 20 cm2). Between the two PVC plates, anodic and cathodic, was placed a rubber spacer, providing a distance of 3 mm, allowing the passage of the solution (Figure 1). The reactor was connected to a recirculation system consisting of a reservoir, a hydraulic pump, and a rotameter to measure the flow of solution in the system (Figure 2). In all experiments, the reactor system operated in the recirculation mode.

To perform the electrochemical degradation of paracetamol was used the electrolysis at constant current through the coupling of a power supply (Tectrol TC 20-05) to the electrochemical reactor system. In this work were used the current densities of 5 and 100 mA cm−2. The flow of the degradation system was set at 50 L h−1 which presents a laminar regime (Reynolds number) of approximately 500. The electrolyte volume was 2.0 L, consisting of 0.1 mol L−1 K2SO4 and 5.0 × 10−4 mol L−1 FeSO4·7H2O containing 2041.2 mg L−1 (1.35 × 10−2 mol L−1) of paracetamol. In all tests was applied a positive flow of N2 (0.2 bar) to GDE by means of the external chamber of the cathode in order to avoid the formation of H2O2 from the cathodic reaction of O2, and that could affect the sensor response [18].

2.4. On-Line Monitoring System: FIA and Reactor Coupling

The FIA/sensor system was coupled to the electrochemical system of degradation (Figure 2), by the reservoir, precisely in the region of sampling of the reactor (E in Figure 2), where the aliquots are usually collected to perform the analyzes of monitoring via off-line. The electrochemical degradation system was refrigerated to maintain a constant temperature at 25°C. Figure 2 shows the diagram of the coupling of the two systems, electrochemical and electroanalytical for the monitoring on-line and at real-time of the paracetamol degradation. The solution/sample from the flow-by electrochemical reactor was injected directly into the analytical system via the sample valve at time intervals pre-established. Prior to filling the sampling loop (75 μL) trapping-bubbles had to be inserted into system to prevent the large number of bubbles formed during the degradation process to entering in the FIA system, which would harm the measurements repeatability. This solution, which leaves the degradation system, travels through the FIA system passing by the injector until it reaches the wall jet cell, where it enters into contact with the biomimetic sensor selective for paracetamol, where are performed amperometric measurements, which is the electroanalytical technique, used to register the FIAgrams. The analyte that is not injected into the electrochemical cell returns to the degradation system by means of the D channel (Figure 2). Thus, keeping a continuous flow of analyte is possible to determine at real-time the amount to paracetamol which is degraded over time.

2.5. HPLC Measurements

In order to validate the results obtained using the proposed on-line system, they were compared to those obtained using the official chromatographic method based on HPLC [19]. Chromatographic analyses were performed using a Shimadzu Model 20A liquid chromatograph coupled to a UV/V detector (SPD-20A), autosampler (SIL-20A), and a degasser DGU-20A5, controlled by a personal computer. A C18 column (250 × 4.6 mm, Shim- Pack CLC–ODS) was used, inside an oven (Shimadzu CTO-10AS) maintained at 30°C. The mobile phase was a mixture of methanol and water in a ratio of 13 : 87 (v/v) with apparent pH of 4.9. The flow rate was 1.0 mL min−1, the sample injection volume 20 μL, and the detector absorption wavelength 254 nm.

The analytical curve was constructed under the same conditions of the degradation. For this, were prepared standard solutions of paracetamol in the electrolyte of degradation (0.1 mol L−1 K2SO4 and 5.0 × 10−4 mol L−1 FeSO4·7H2O) contained between 1.0 × 10−4 mol L−1 (15.2 mg mL−1) and 5.0 × 10−2 mol L−1 (7560 mg mL−1). The equation of the analytical curve was used to calculate the concentration in the samples collected from the electrochemical reactor at different pre-established times of electrolysis.

The samples were collected from the reactor at the same periods of sampling realized in the on-line system and immediately frozen until the realization of the chromatographic experiments. Samples collected from degradation at 5 mA cm−2 were analyzed by HPLC two days after the electrolysis, and the samples at 100 mA cm−2 were examined five days after the electrolysis, becoming an obvious disadvantage of this method.

2.6. UPLC/MS Measurements

For these studies, aliquots of the degradation using the DSA-Cl2 electrode were collected at 0, 30, 60, and 90 minutes and were immediately analyzed on a Waters UltraAcquity chromatograph, equipped with a binary pump, a C18 reversed phase column Acquity UPLC-BEH (2.1 × 50 mm and 1.7 μm particle size) maintained at 37°C, and a degasser.

Previously, in order to obtain the highest signal and the lowest retention time, the UPLC/MS conditions were optimized. For this, firstly was optimized the ionization process (conversion of the analyte in solution to the gas phase directly in the ionization source), which should preferably take place without occurring of fragmentation, in order to obtain information on the molar mass of the compounds analyzed. Thus, was carried out the direct injection of 500 μL of solution of paracetamol in the electrospray source at a flow rate of 20 μL min−1. Additionally, the following chromatographic conditions were also optimized, in order to obtain the best process of separation with the lowest retention time the flow rate and mobile phase in the gradient mode.

Thus, with all parameters optimized the chromatographic analysis was performed at 0.350 mL min−1 in the gradient mode, using different mixtures of 0.1% (v/v) formic acid in water (solvent A) and 0.1% (v/v) formic acid in acetonitrile (solvent B), with the programation described follow as: initially between 0 and 4 min, 70% (a) and 30% (b); 4–6 min, 30% (a) and 70% (b); and in last minute (6-7 min) 95% (a) and 5% until reaching the initial proportions of 70% (a) and 30% (b), respectively. Although the chromatographic run was performed for 7 minutes, in order to explore a long period of time and check if other substances would be generated during the electrolysis of paracetamol, the only peaks appeared during the first minute of running, as will be shown in Figure 7.

Additionally, the experimental conditions of the mass detector were as follows: (i) polarity: positive, ES + mode; (ii) capillarity to 1.00 kV; (iii) cone voltage: 30 V; (iv) supply temperature: 120°C; (v) desolvation temperature: 350°C; (v) Gas used in the cone and desolvation: N2 and the gas flow on the cone: 100 L Hr−1; (vi) desolvation gas flow 800 L Hr−1; and (vii) photomultiplier voltage: 650 V.

For analysis of the degradation samples, they were diluted 500 times, in order to avoid saturation of the detector. In the case of the sample collected before starting the electrolysis (), the initial concentration was 4.08 μg mL−1. The concentration of standard solution of paracetamol was 1.0 μg mL−1.

2.7. GC/MS Measurements

For these studies, aliquots of the degradation at 0, 30, and 60 minutes of electrolysis were taken from the reactor and after a process of liquid-liquid extraction were analyzed by a gas chromatograph model CP-3800 Varian coupled to an ion trap mass spectrometer Varian model Saturn 2100D and using a column of 30 m × 0.25 mm × 0.25 μm, whose stationary phase consisted to a mixture to diphenyl (5%)-dimethyl (95%)-polysiloxane (CP-Sil CB8, Low Bleed).

The experimental conditions were as follows: (i) injector at 260°C in split mode of 1 : 25 and flow of 1.0 mL min−1; and (ii) Programation of the oven: 80°C (1.0 minutes), ramp heating 10°C min−1 up to 280°C, and maintained at that temperature for 5 minutes. Total time to run: 26 minutes. (iii) Detector: Ion Trap MS type, 70 eV, solvent delay 2.5 min, scan range 40–450 Da.

For the analysis by GC/MS the samples were extracted in 500 μL of dichloromethane. For each sample, six successive extractions were performed to each aqueous extract in an Eppendorf of 2 mL. After the extraction performed, the organic phase was dried with MgSO4 and then injected 0.6 μL into equipment. For comparative studies was prepared a solution of paracetamol in dichloromethane (0.2 mg mL−1) and injected 0.6 μL into equipment.

3. Results and Discussion

3.1. Analytical Profile of the FIA/Sensor System

Firstly, before coupling the sensor to the system of electrochemical degradation, the analytical conditions had to be adjusted in order to obtain results more reliable and reproducible, since in this case the samples from the electrochemical reactor were in 0.1 mol L−1 K2SO4 and 5.0 × 10−4 mol L−1 FeSO4·7H2O (degradation electrolyte). In this way, was evaluated the response of the system FIA/sensor in this electrolyte, and thus to continue with the studies of the on line coupling of the electrochemical and electroanalytical systems. The results obtained are shown in Figure 3, in which are present the FIA signals as a function of paracetamol concentration using the degradation electrolyte like carrier solution.

Although the sensitivity of the system has decreased when compared to the optimized FIA system, that uses 0.1 mol L−1 acetate buffer at pH 3.6 as carrier [12], the response of the FIA/sensor system under this new adjusted condition was also reproducible and sufficiently sensitive for this application proposed. The data presented in Figure 3 were linearly adjusted to a straight line, whose linear regression, in direction of increasing concentration, is shown in (1):

3.2. The Paracetamol Degradation Used a Flow-By Electrochemical Reactor

The degradation of paracetamol in the electrochemical reactor is based on the oxidation process of the drug on the surface of the anode DSA-Cl2. The use of a GDE as cathode aimed to compose the electric circuit in the reactor without interference in the process of degradation of the organic matter present in the electrolyte.

In this work was carried out electrolysis at current densities at two extreme values (5 and 100 mA cm−2) using as electrolyte the solution of K2SO4 0.1 mol L−1 and FeSO4·7H2O 5.0 × 10−4 mol L−1, aiming to allow the complete oxidation of the paracetamol.

The results obtained at 5 mA cm−2 practically does not present significant variation of the paracetamol concentration after the first 20 minutes of the electrochemical degradation begin, monitored via FIA/sensor and HPLC (Table 1). On the other hand, as expected, results more relevant were obtained when was applied a current density of 100 mA cm−2, and in this work will be presented the results obtained in this condition.

3.3. Coupling of FIA/Sensor to the Flow-By Electrochemical Reactor

To evaluate the performance of the flow injection system with biomimetic detection in the on-line monitoring of the paracetamol degradation performed in an electrochemical reactor at pilot scale, both systems were coupled as described in Section 2.4 (Figure 2).

In this case, the measurements were performed injected directly into the FIA system (flow rate of 1.25 mL min−1) 75 μL of the solution/sample from the electrochemical degradation system. Figure 4(a) shows the signals obtained at real-time by the FIA system for the paracetamol degradation at 100 A cm−2. Figure 4(b) shows the corresponding graph of the current variation at function of time. The three initial injections correspond to the signals obtained before the start of electrolysis () and served to verify the stability of the on-line system. With the data shown in Figure 4(b) and using (1), we could verify that the graph ln[Paracetamol] versus time shows a linear adjustment whose equation is given as follows (2), suggesting that the kinetics of electrochemical degradation of paracetamol follows a behavior of pseudo-first order [20]:

In (2) it is verified that the linear coefficient corresponds to ln[Paracetamol]0 providing the value of 0.0133 mol L−1 of paracetamol, initially added in the electrochemical reactor. The slope corresponds to an apparent constant of the pseudo-first order of 7.4 min−1. A great advantage of this proposed on-line system is that a great number of points can be monitored in comparison with the chromatographic off-line method, and thus all constants found for the electrochemical degradation will be more accurate, because they will be based on a larger number of data.

3.4. Quantification of Paracetamol Employed the Official Method of Analysis (Off-Line) in the Electrolysis Performed in the Flow-By Electrochemical Reactor

Analyzes were performed to quantify paracetamol using the official method of analysis based on high-performance liquid chromatography (HPLC), with the purpose of comparing the results obtained with the proposed online system. Figure 5 shows the decay profiles of normalized concentrations of paracetamol as a function of electrolysis time, obtained by the two methodologies here used, HPLC (off-line) and the proposed (on-line). In Table 2, also are show some paracetamol concentrations obtained through the two methodologies used. Based on these results, is evident a great difference between the methodologies.

The difference can be explained if we consider that the samples analyzed by the off-line method were carried out only five days after the collect. In addition, if we observed the chromatograms obtained for the degradation samples at different periods (Figure 6) a formation of a second peak at 12.6 min (2 in Figure 6) very close to the retention time of paracetamol at 13.2 min (1 in Figure 6), causes the calculation of peak area of paracetamol to be wrong, providing a value greater concentration and thus giving an inexact profile of the degradation.

On the other hand, it should be emphasized that the on-line system is not influenced by the presence of degradation product 2 (Figure 6) or others, due to the high selectivity shown by the biomimetic sensor used as the detector in the electroanalytical system [10, 12]. At the same time, the results of electrochemical degradation of paracetamol are obtained and recorded in real-time just after the output of reactor, avoiding sample contamination and parallel reactions occur in the collected samples.

In this way, the advantages offered by this on-line system proposed to monitor degradation experiments are evident, opening a new alternative for the conventional and off-line monitoring methodologies.

3.5. Identification of Products Formed in the Paracetamol Degradation Using Hyphenated Techniques: UPLC/MS and GC/MS

In order to identify the degradation products of paracetamol at 100 A cm−2 and, consequently, to show the sensor selectivity used as the detector in the FIA system, was initially used the Ultra performance liquid chromatography (UPLC) coupled to mass spectrometry (Figures 7 and 8).

In Figure 7 are shown the chromatograms obtained for a standard solution of 1.0 mg mL−1 paracetamol (Figure 7(a)) and from samples collected at 0 min (Figure 7(b)), 30 min (Figure 7(c)), 60 min (Figure 7(d)), and 90 min (Figure 7(e)) of degradation. It is again possible to observe the two peaks in the degradation samples at 0.40 and 0.45 minutes (Figures 7(c)7(e)). The first peak increases with electrolysis time, such expected (the degradation compound formed), and the second peak corresponds to paracetamol, as verified by, Figures 7(a), 7(b), and 8(b).

Analyzing the peak at 0.40 min (Figure 8(a)) using electrospray mass spectrometry in positive mode (ESI+) shows that this corresponds to the acetamide compound ([M + H]+ = 60), which is consistent with the loss of this group on the molecule of paracetamol (Scheme 1). For comparison purposes, is shown in Figure 8(b), the mass spectrum for the paracetamol (at 0.45 min). Comparing both figures one can see clearly the difference in the mass spectra corresponding to each one these molecules. In this way, the results obtained by UPLC/MS suggest that acetamide is a product in the electrochemical degradation, which, being detected by liquid chromatography, causes errors in the calculation of the area, and consequently in the estimated concentration for paracetamol.

171389.sch.001

Moreover, in order to verify what would be the additional degradation product, corresponding to the remaining portion of the paracetamol molecule, experiments were performed using GC/MS, due to that in liquid chromatography was not possible to identify other molecules formed (Figures 6 and 7). Thus, using gas chromatography, after performing successive extractions in dichloromethane in the sample of 60 min of electrolysis, was observed a peak at the retention time of 3.471 min (Figure 9(b)) which is different from the retention time observed for the standard solution of paracetamol, which occurs at 13.4 min (Figure 9(a)). To identify the product that is formed, was analyzed the peak in Figure 9(b) by mass spectrometry and identified according to the library NIST 2005 as p-benzoquinone, such as shown in inset in Figure 9(b). Already for comparison purposes was also analyzed the peak corresponding to paracetamol, and the corresponding mass spectrum is shown in Figure 10.

In Scheme 1 a mechanism for the degradation of the paracetamol based on experimental evidences obtained by chromatographic methods coupled to mass spectrometry is proposed. The experiments suggested the presence of p-benzoquinone and acetamide, on the collected samples after 60 and 90 min of electrolysis, respectively. The mechanism suggests that initially is promoted a cleavage of the molecule of paracetamol releasing acetamide ([M + H]+ = 60) and probably generated the p-hydroquinone molecule that is immediately oxidized to p-benzoquinone (, inset Figure 9(b)).

It should be emphasized that the proposed sensor does not detect the presence of acetamide or hydroquinone and p-benzoquinone during electroanalytical measurements, which makes it, in fact, an alternative tool to the traditional methods monitor the degradation processes, and that which can lead to obtain erroneous results, for example, in the profile of degradation, in calculation of some constant, and even in the current or potential of electrolysis that should be applied to obtain satisfactory results.

4. Conclusions

It should be emphasized that this study used as a model system the degradation of paracetamol only to demonstrate and/or evaluate the feasibility and benefits of the on-line coupling of a highly selective FIA system to a system of electrochemical degradation, which can be extended to other pollutants and other degradation processes.

The system offers the advantage of monitoring the drug concentrations in real-time, when compared to the reference method. Lastly, commonly the monitoring analyses are performed off-line and sometimes several days after that the electrolyses were performed, not reflecting the actual values obtained. In the proposed system, really reliable results are obtained once has been used a selective sensor, robust and easily constructed, that allowed obtaining a cheap, fast, and environmentally friendly method for real-time monitoring of electrochemical degradation of paracetamol.