Research Article
Selection of the Best Process Stream to Remove Ca2+ Ion Using Electrodialysis from Sugar Solution
Table 2
Different process variables chosen during ED experimentation [
13].
| Expt. number | Feed solution | Feed flow rate (mL·min−1) | Anolyte solution | Anolyte flow rate (mL·min−1) | Catholyte solution | Catholyte flow rate (mL·min−1) | Voltage applied (V) | Time (min) |
| 1 | 25 mol·m−3 CaCl2 in 5% sugar solution | 130 | 100 mol·m−3 HCl solution | 830 | 100 mol·m−3 NaOH solution | 830 | 4 | 685 |
| 2 | 25 mol·m−3 CaCl2 in 5% sugar solution | 130 | 100 mol·m−3 HCl solution | 830 | 25 mol·m−3 Na2EDTA + 25 mol·m−3 AA solution | 830 | 4 | 240 |
| 3 | 50 mol·m−3 CaCl2 in 5% sugar solution | 130 | 100 mol·m−3 HCl solution | 830 | 50 mol·m−3 Na2EDTA + 50 mol·m−3 AA solution | 830 | 4 | 240 |
|
|