Research Article

Relevance Vector Machine Based Analyses of MRR and SR of Electrodischarge Machining Designed by Response Surface Methodology

Table 8

Regression test error for number of iterations.

For cubic kernel function, noise factor = 0.01
No. of iterationsRegression test error for MRRRegression test error for SR

1000.0120260.018637
2000.0106940.015266
2500.012930.015358