GroupTest numberReactivity ($)Period (msec) (°C)Flow (gpm)Initial power (W)

1B10.8098019.001
B20.8859820.001
B30.9237421.801
B40.9819020.901
B51.0410722.201
B61.1162.422.401
B71.1549.822.201
B81.2629.622.401
B91.4019.622.401
B101.5315.820.501
B111.5414.522.200.001
B121.6811.722.300.001
B131.8210.122.200.001
B141.918.4822.000.001
B152.007.8319.900.001
B162.147.019.800.001
B171.4021.32201
B181.6812.021.800.001
B191.918.8321.700.001

2B200.8856021.95001
B211.1454.222.85001
B221.6611.923.35000.001
B231.8010.123.25000.001

3B240.885292210001
B251.0410322.510001
B261.1454.522.810001
B271.3920.02310001
B281.6612.322.910000.001
B291.8010.422.910000.001

4B300.8853122.525001
B311.1452.122.725001
B321.6612.222.625000.001
B331.8010.023.225000.001

5B340.8851621.950001
B351.0510422.050001
B361.1449.322.450001
B371.3920.720.750001
B381.6612.223.450000.001
B391.8010.123.750000.001