Transient tests for SPERT IV.
| Group | Test number | Reactivity ($) | Period (msec) | (°C) | Flow (gpm) | Initial power (W) |
| 1 | B1 | 0.80 | 980 | 19.0 | 0 | 1 | B2 | 0.88 | 598 | 20.0 | 0 | 1 | B3 | 0.92 | 374 | 21.8 | 0 | 1 | B4 | 0.98 | 190 | 20.9 | 0 | 1 | B5 | 1.04 | 107 | 22.2 | 0 | 1 | B6 | 1.11 | 62.4 | 22.4 | 0 | 1 | B7 | 1.15 | 49.8 | 22.2 | 0 | 1 | B8 | 1.26 | 29.6 | 22.4 | 0 | 1 | B9 | 1.40 | 19.6 | 22.4 | 0 | 1 | B10 | 1.53 | 15.8 | 20.5 | 0 | 1 | B11 | 1.54 | 14.5 | 22.2 | 0 | 0.001 | B12 | 1.68 | 11.7 | 22.3 | 0 | 0.001 | B13 | 1.82 | 10.1 | 22.2 | 0 | 0.001 | B14 | 1.91 | 8.48 | 22.0 | 0 | 0.001 | B15 | 2.00 | 7.83 | 19.9 | 0 | 0.001 | B16 | 2.14 | 7.0 | 19.8 | 0 | 0.001 | B17 | 1.40 | 21.3 | 22 | 0 | 1 | B18 | 1.68 | 12.0 | 21.8 | 0 | 0.001 | B19 | 1.91 | 8.83 | 21.7 | 0 | 0.001 |
| 2 | B20 | 0.88 | 560 | 21.9 | 500 | 1 | B21 | 1.14 | 54.2 | 22.8 | 500 | 1 | B22 | 1.66 | 11.9 | 23.3 | 500 | 0.001 | B23 | 1.80 | 10.1 | 23.2 | 500 | 0.001 |
| 3 | B24 | 0.88 | 529 | 22 | 1000 | 1 | B25 | 1.04 | 103 | 22.5 | 1000 | 1 | B26 | 1.14 | 54.5 | 22.8 | 1000 | 1 | B27 | 1.39 | 20.0 | 23 | 1000 | 1 | B28 | 1.66 | 12.3 | 22.9 | 1000 | 0.001 | B29 | 1.80 | 10.4 | 22.9 | 1000 | 0.001 |
| 4 | B30 | 0.88 | 531 | 22.5 | 2500 | 1 | B31 | 1.14 | 52.1 | 22.7 | 2500 | 1 | B32 | 1.66 | 12.2 | 22.6 | 2500 | 0.001 | B33 | 1.80 | 10.0 | 23.2 | 2500 | 0.001 |
| 5 | B34 | 0.88 | 516 | 21.9 | 5000 | 1 | B35 | 1.05 | 104 | 22.0 | 5000 | 1 | B36 | 1.14 | 49.3 | 22.4 | 5000 | 1 | B37 | 1.39 | 20.7 | 20.7 | 5000 | 1 | B38 | 1.66 | 12.2 | 23.4 | 5000 | 0.001 | B39 | 1.80 | 10.1 | 23.7 | 5000 | 0.001 |
|
|