Research Article
Modeling of SPERT IV Reactivity Initiated Transient Tests in EUREKA-2/RR Code
Table 2
Channel distributions in EUREKA-2/RR.
| Fuel cell number | Radial peaking factors (MVP) | Channels | Number of fuel cells | Number of fuel plates |
| E6 | 1.37322 | 1 | 1/12 | 1 |
| E6 | 1.37322 | 2 | 7 + 11/12 | 95 | F5 | 1.37105 | E4 | 1.36998 | D5 | 1.36887 | E7 | 1.15432 | G5 | 1.14816 | E3 | 1.14151 | C5 | 1.13272 |
| D7 | 1.04837 | 3 | 10 | 120 | F7 | 1.04519 | D3 | 1.04256 | G6 | 1.04235 | F3 | 1.04180 | G4 | 1.04120 | C6 | 1.03932 | C4 | 1.03897 | C7 | 0.83797 | G3 | 0.83581 |
| C3 | 0.83525 | 4 | 4 | 36 | G7 | 0.83392 | E5 | 0.81652 | F6 | 0.61168 |
| D6 | 0.61119 | 5 | 3 | 18 | F4 | 0.60960 | D4 | 0.60847 |
|
|