Clinical Study

Hearing Benefit in Allograft Tympanoplasty Using Tutoplast Processed Malleus

Table 1

Comparison between pre- and postoperative audiograms and assessment of air-bone gap.

Patient
1234567MeanSD

Operated ear
Preoperative hearing (air conduction; 500–4000 Hz)5041557354383649.512.7
Preoperative air-bone gap (500–4000 Hz)3023284338343532.76.6
Follow-up (months)34262929202215256
Postoperative hearing (air conduction; 500–4000 Hz)2828394528191929.1 a9.7
Postoperative air-bone gap (500–4000 Hz)18524141591313.8 b6.0
Air-bone gap closure achieved 131842923252318.98.5

a ; b . Bold: Mean values. Italic: Standard deviation.