Research Article
Photovoltaic System Modeling with Fuzzy Logic Based Maximum Power Point Tracking Algorithm
Table 2
The resultant output voltage, current, and power at different irradiation for standard test temp (25°C) for the selected three PV modules.
|
Irradiation at 25°C temp. | SOLKAR-36 W PV module | BP MSX-60 W PV module | KYOCERA KC85T-87 W PV module | Maximum current () | Maximum voltage () | Maximum power () | Maximum current () | Maximum voltage () | Maximum power () | Maximum current () | Maximum voltage () | Maximum power () |
| 1000 W/m2 | 1.029 | 36 | 37.02 | 1.739 | 33.04 | 57.45 | 2.527 | 34.238 | 86.52 | 800 W/m2 | 0.932 | 32.6 | 30.4 | 1.48 | 28.11 | 41.6 | 2.111 | 27.44 | 57.92 | 500 W/m2 | 0.624 | 21.85 | 13.64 | 0.9399 | 17.86 | 16.79 | 1.348 | 17.53 | 23.63 | 300 W/m2 | 0.3754 | 13.14 | 4.93 | 0.5642 | 10.72 | 6.048 | 0.8017 | 10.42 | 8.532 |
|
|