Research Article

Top-Emission Organic Light Emitting Diode Fabrication Using High Dissipation Graphite Substrate

Figure 4

Temperature when (a) the glass (b) copper or (c) graphite substrate device is operated. Lift is operated for 5 seconds; right is operated for 25 seconds.
319390.fig.004a
(a) Glass
319390.fig.004b
(b) Copper
319390.fig.004c
(c) Graphite