A Simple Approach in Estimating the Effectiveness of Adapting Mirror Concentrator and Tracking Mechanism for PV Arrays in the Tropics
Table 1
Specifications of 1 kWp PV generator system.
Fixed Flat PV (FF)
Tracking flat PV (TF)
Concentrating PV (CPV)
(i) Common flat PV array (ii) Series connecting 12 units of CEEG 95 W monocrystalline module (iii) Built-up area: 3.6 m × 2.4 m (iv) Rated power: 1 kW (v) : 22.5 V × 12 = 270 Vdc (vi) : 5.56 Adc (vii) : 1.5 kW (rated at STC)
(i) Dual-axis sun tracking (ii) Series connecting 12 units of CEEG 95 W monocrystalline module (iii) Built-up area: 3.6 m × 2.4 m (iv) Rated power: 1 kW (v) : 22.5 V × 12 = 270 Vdc (vi) : 5.56 Adc (vii) : 1.5 kW (rated at STC)
(i) Dual-axis sun tracking with mirror concentrator (ii) Series connecting 6 units of CEEG 95 W monocrystalline module (iii) Built-up area: 3.6 m × 2.4 m (iv) Rated power: 1 kW (v) : 22.5 V × 6 = 135 Vdc (vi) : 5.56 Adc (vii) : 0.75 kW (rated at STC)