Research Article

The Synergistic Effect of Thermal Collectors Rotation in relation to Their Energy Efficiency and Stagnation Compared with the Static Thermal System in the Conditions of Central Europe

Table 2

The measured values of the solar radiation intensity and the amount of the gained energy.

HourDate
20/3/201421/3/201422/3/201423/3/201424/3/20142/4/20143/4/2014

RotationRadiation intensity klx724.5544928.0757620.6754510.6311411.569468.8357144.292857
845.7550947.9694640.5748518.350342.2580827.7857119.74286
965.1708364.375656.2607119.7648854.17546.6428635.90714
1072.4616873.8886269.4053932.8137756.6802461.4571458.35714
1165.563173.1654872.8083341.9511912.4648871.7714367.44286
1260.4904267.0359364.9844330.698812.4437175.0714361.72857
1350.7488152.4220247.7154824.295835.59047664.8214347.82857
1433.4808431.200628.8604823.35211.2247.9071442.07143
1514.462515.8075513.512864.3541.12530.2615421.85385
165.1504133.9113.4951.350.916.9913.871
Gained energy MJ791050100
81112901051
9151412111108
10161512351312
11141312751512
12131210421413
13119720106
148773066
154350012
163000000
= 466 MJ

26/3/201427/3/201428/3/201429/3/201430/3/201431/3/20141/4/2014

FixRadiation intensity klx725.2395218.1712615.9874322.429348.0574857.2958088.468
843.0556938.6940144.6946145.0029931.4323422.1880221.66946
955.9702443.3464364.1595262.1101251.7607135.0309533.88155
1066.6053948.3155755.2808476.7041969.9574943.3299448.02575
1153.9190548.1464348.9267978.8886978.9410754.845.92083
1255.5682646.8461155.1419269.1802478.7820436.4610852.71018
1343.5714338.7214344.1660751.7488168.4446425.112556.28571
1412.3125728.3748529.2287433.3886250.3736532.3445.49641
1515.6911.8612.5914.1633.194299.76430.36929
163.8633.246.1636.4515.5114.068.48
Gained energy MJ77225110
81181110634
912813131267
1013511141569
1110841516106
1210710111558
1376571129
140121706
150000101
160000000
= 416 MJ