Table 2

Concentrations of polycyclic aromatic hydrocarbons in biologically treated landfill leachate and after different Fenton-based treatments (g L−1).

Polycyclic aromatic hydrocarbonsStructureRaw leachateFentonUV-FentonMDEL-Fenton

2-Vinylnaphthalene0.55 0.240.10 ± 0.040.03 ± 0.01N.D.

Naphthalene 0.41 ± 0.150.26 ± 0.160.14 ± 0.010.05 ± 0.02

1-Methylphenanthrene0.16 ± 0.030.09 ± 0.040.06 ± 0.01N.D.

Acenaphthylene 0.19 ± 0.070.10 ± 0.040.09 ± 0.040.05 ± 0.02

Acenaphthene 4.78 ± 1.230.17 ± 0.070.16 ± 0.110.10 ± 0.03

Fluorene 4.62 ± 1.430.19 ± 0.040.09 ± 0.040.06 ± 0.02

Phenanthrene 0.24 ± 0.13N.D.N.D.N.D.

Anthracene 3.29 ± 0.160.27 ± 0.070.19 ± 0.050.05 ± 0.02

Fluoranthene 0.84 ± 0.130.05 ± 0.010.11 ± 0.03N.D.

1-Methylpyrene0.11 ± 0.05N.D.N.D.N.D.