Investigation of Photovoltaic Assisted Misting System Application
for Arbor Refreshment
Table 4
Typical electrical characteristics of BSM-150 PV module.
Parameter
Variable
Value
Maximum power
150 W
Power tolerance
%
+5
Max power voltage
(V)
18.11
Max power current
(A)
8.32
Open circuit voltage
(V)
22.51
Short circuit current
(A)
9.08
Max system voltage
VDC
1000
Cell efficiency
(%)
≥17
Cell size
Mm
156 × 156
temperature coefficient
(%/°C)
+0.1
temperature coefficient
(%/°C)
−0.38
temperature coefficient
(%/°C)
−0.47
temperature coefficient
(%/°C)
+0.1
temperature coefficient
(%/°C)
−0.38
NOCT, nominal operating cell temperature
°C
48 ± 2
Fill factor
%
≥73.3
The data are based on measurements made in a solar simulator at standard test conditions (STC), which are (i) illumination of 1 kW/m2 (1 sun) at spectral distribution of AM 1.5; (ii) cell temperature of 25°C or as otherwise specified (on curves).