Research Article
Effect of Installation of Solar Collector on Performance of Balcony Split Type Solar Water Heaters
Table 3
Technical index of TRM-2 thermal performance testing system of solar water heaters.
| | Measurement range | Measurement accuracy | Resolution | Other parameters |