Research Article

Effect of Installation of Solar Collector on Performance of Balcony Split Type Solar Water Heaters

Table 5

Performance of solar water heater with flat-plate collector at a fixed surface slope angle of 90° under natural circulation and forced circulation.

DateNatural circulation Forced circulation
Jan. 24Jan. 25Feb. 3Feb. 4

Ambient average temperature (°C)17.316.617.416.6
Average wind speed (m/s)0.60.71.11.4
Irradiance (MJ)17.615.815.715.3
Time (hr)6.06.06.06.0
Initial temperature of tank (°C)14.313.816.219.6
Final temperature of tank (°C)24.422.942.344.8
Temperature rise (°C)10.19.126.125.2
Efficiency0.2180.2190.6290.654
Useful energy (MJ)5.084.5613.1212.64
Consumption of energy (MJ)0.00.01.731.73