Research Article

Grid-Connected Semitransparent Building-Integrated Photovoltaic System: The Comprehensive Case Study of the 120 kWp Plant in Kunming, China

Table 2

Environmental benefit measurement and relevant parameters for the BIPV system.

The major emission pollutantsEmission rate of pollutants (kg/kgce)Emission reduction density (kg/kWh)Emission density (kg/kWh)Environmental values of pollutants (RMB yuan/kg)Environmental cost of generation (RMB yuan/kWh)Environmental benefits of emission reduction (RMB yuan/kWh)

CO21.7312.127 × 10−17.986 × 10−22.3 × 10−20.184 × 10−34.893 × 10−3
SO20.0182.212 × 10−38.304 × 10−464.983 × 10−31.327 × 10−2
NOx0.0089.832 × 10−43.691 × 10−482.953 × 10−37.866 × 10−3
CO0.000263.195 × 10−51.199 × 10−511.199 × 10−53.195 × 10−5
Particulate0.111.351 × 10−25.075 × 10−31.2 × 10−16.090 × 10−41.622 × 10−3
Slag0.033.687 × 10−31.384 × 10−31.0 × 10−11.384 × 10−43.687 × 10−4
Total////1.053 × 10−22.805 × 10−2