Research Article
Research on Parameter Extraction Method of Photovoltaic Module Based on Improved Hybrid Algorithm
Table 7
Time on extracting parameters from three kinds of PV modules by different methods.
| Method | Modules | Irradiance (W/m2) | Temperature (°C) | Time (ms) |
| DE | SP75 | 1000 | 25 | 2.845 | DE | SP75 | 600 | 25 | 2.745 | DE | SP75 | 1000 | 20 | 2.796 | DE | SP75 | 1000 | 60 | 3.124 | IDE | SP75 | 1000 | 25 | 1.975 | IDE | SP75 | 600 | 25 | 1.854 | IDE | SP75 | 1000 | 20 | 1.842 | IDE | SP75 | 1000 | 60 | 2.026 | DE | S25 | 1000 | 25 | 2.762 | DE | S25 | 600 | 25 | 2.975 | DE | S25 | 1000 | 20 | 2.874 | DE | S25 | 1000 | 60 | 2.975 | IDE | S25 | 1000 | 25 | 1.696 | IDE | S25 | 600 | 25 | 1.852 | IDE | S25 | 1000 | 20 | 1.796 | IDE | S25 | 1000 | 60 | 1.927 | DE | ST36 | 1000 | 25 | 2.951 | DE | ST36 | 600 | 25 | 3.246 | DE | ST36 | 1000 | 20 | 2.987 | DE | ST36 | 1000 | 60 | 2.994 | IDE | ST36 | 1000 | 25 | 1.786 | IDE | ST36 | 600 | 25 | 1.954 | IDE | ST36 | 1000 | 20 | 1.997 | IDE | ST36 | 1000 | 60 | 1.849 |
|
|