Research Article
Influence of Inclination Angle at the Chimney Inlet on the Power Generation in Solar Chimney Power Plants through 3D CFD Model
Table 2
Characteristics of the components utilized in CFD simulation [
29].
| Properties | Chimney | Collector | Ground |
| Thermal conductivity (W/mK) | 202.4 | 1.15 | 1.83 | Specific heat (J/kg K) | 871 | 750 | 710 | Density (kg/m3) | 2719 | 2500 | 2160 | Absorption coefficient | 0 | 0.03 | 0.9 | Emissivity | 1 | 0.9 | 0.9 | Transmissivity | ā | 0.9 | ā | Refractive index | 1 | 1.516 | 1 |
|
|