Research Article
A Programmable Look-Up Table-Based Interpolator with Nonuniform Sampling Scheme
Table 1
Frequency assignment for sampling scheme
.
| | | |
| 1 | −1.00000000000000 | 32768 | 2 | −0.99770000000000 | 16384 | 3 | −0.99540000000000 | 8192 | 4 | −0.99030000000000 | 4096 | 5 | −0.98050000000000 | 2048 | 6 | −0.95900000000000 | 1024 | 7 | −0.91410000000000 | 512 | 8 | −0.82040000000000 | 256 | 9 | −0.64070000000000 | 128 | 10 | −0.34380000000000 | 64 | 11 | −0.12510000000000 | 32 | 12 | +0.00000000000000 | 32 | 13 | +0.12490000000000 | 64 | 14 | +0.34360000000000 | 128 | 15 | +0.64050000000000 | 256 | 16 | +0.82020000000000 | 512 | 17 | +0.91400000000000 | 1024 | 18 | +0.95890000000000 | 2048 | 19 | +0.98040000000000 | 4096 | 20 | +0.99010000000000 | 8192 | 21 | +0.99530000000000 | 16384 | 22 | +0.99760000000000 | 32768 | — | +0.99993896484375 | — |
|
|