Research Article

Experimental Investigation and Passive Flow Control of a Cavitating Centrifugal Pump

Table 1

Main characteristics of the tested impellers.

Impeller characteristicsValues

Suction pipe diameter , mm100
Diameter of the impeller at the suction side , mm108
Diameter of the impeller at the pressure side , mm180
Impeller width at the suction side , mm15.6
Impeller width at the pressure side , mm15.6
Blade leading edge angle , deg9, 15, 21
Blade trailing edge angle , deg20
Maximum blade thickness , mm7.5
Number of blades 5